HomeAbout Us
Facilities & SolutionsCustomersCareersContact
Request a quote
Product

AUTO TRANSFORMER FOR STATER

AUTO TRANSFORMER FOR STATER
1 / 2
Specifications
Standard
IS 5142
Type
Three-phase auto-transformer starter
Capacity
5 kVA – 500 kVA
Input Voltage
415 V, 3-phase, 50 Hz
Voltage Taps
50%, 65%, 80% (standard)
Duty
Short-time (motor starting)
Insulation Class
Class F / H
Core Material
CRGO silicon steel laminations

Exact specifications depend on the variant and order. Contact us for a detailed datasheet.

Overview

Reduced-voltage starting for large motors — without the torque penalty of star-delta.

An auto-transformer starter reduces the voltage applied to a large squirrel-cage induction motor at start-up, limiting the inrush current that would otherwise stress the supply network, trip upstream protection, and cause voltage dips that affect other equipment. Standard taps at 50%, 65%, and 80% of supply voltage reduce starting current to 25%, 42%, and 64% of the DOL value respectively. Unlike a star-delta starter, the motor receives voltage from the transformer secondary — not from a re-wired winding — so it can develop full starting torque at any tap position. This makes auto-transformer starting the preferred choice for loaded conveyors, compressors, and high-inertia loads where star-delta starting torque is insufficient.

Sakthi manufactures auto-transformer starters from 5 kVA to 500 kVA with open frame or enclosed construction, wound on CRGO laminated cores with Class F or H insulation. The starter is timed by a contactor-and-timer circuit — after a settable acceleration time, the circuit transitions to direct supply. Custom tap positions and panel-mounted automatic starters with ammeters and timers are available on request.

Where it's used

Typical applications

Reduced Voltage Motor Starting

Steps down supply voltage to 50–80% to limit starting current of large squirrel-cage induction motors where DOL is not permitted.

Pumps & Compressors

Used to start high-inertia loads like centrifugal pumps, blowers, and air compressors in industrial plants and waterworks.

HVAC & Ventilation

Reduces starting torque and current surge for large HVAC fans, chillers, and cooling tower motors.

Automatic Starter Panels

Integrated into automatic reduced-voltage starter panels with timers and contactors for fully automatic starting cycles.

Need a custom specification?

Tell us your spec. We'll build to it.

Share your ratio, accuracy class, burden and standard — our engineering team will quote the right unit.

Request a quoteTalk to engineering